Mission #75 (OTN200)

Status
  • Battery: 11.1477 -> 10.8341 V
  • AmpHrs:
  • LeakDetect: OK
  • Vacuum: -1 inHg

Mission Diagnostics Page

Mission ran from (2017-08-02 19:37:38 til 2017-11-09 17:04:00)
Posted By:
jvandermeer @
2017-08-06 23:08:28
Adam, Jude and Tara deployed otn200 in Roseway Basin from OceanTracker off Cape Sable Island- mission start: 02 August 2017 at 19:37:38 UTC
jvandermeer @
2017-08-06 23:09:07
otn200 was struggling to reach wpt 1 and has been sent to wpt 2. goto_l10 was also updated to have the glider loop through waypoints forever.
jvandermeer @
2017-08-11 14:24:19
Mike and otn200 have completed their initial tandem mission. As such, a new goto_l10.ma list has been uploaded as specified by Tara Howatt, ('Roseway2017-OTN200.kmz'). otn200 will now loop through 12 wpts running NW to SE across the Roseway Basin.
jvandermeer @
2017-08-14 14:39:28
As per Kim's request I have updated the fin settings from the default: u_heading_deadband 0.087 (rad), u_heading_rate_deadband 0.0087 (rad/s), u_hd_fin_ap_run_time -1, u_hd_fin_ap_deadband_reset 0, to the fin settings specified by Mark and currently set up with dal556: u_heading_deadband 0.261, u_heading_rate_deadband 0.0261, u_hd_fin_ap_deadband_reset 1, u_hd_fin_ap_fun_time 120 (s).
jvandermeer @
2017-08-21 16:44:18
In an effort to reduce power usage and extend mission longevity, both fluorometers & the OCR have been shut down while the optode's sampling has been reduced to once every surfacing. sample(13, 14, 15).ma: intersample_time(s) -1 (off) sample16.ma: nth_yo_to_sample 20
acomeau @
2017-08-24 13:01:18
On the next surfacing the glider should start sampling the ctd on while diving and climbing.

Latest Mission Data

Temperature

Pot. Density

Salinity

Oxygen Saturation

Chl a from Fluorescence

Irradiance